1. The irradiation distance of the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical lightp is generally about 70-140 cm (that is, the Fepdon Geeta Series LED surgical lighting lamp equipment surgical light has the best shadowless effect within this distance).

2. The larger the lamp panel of the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light (single head lamp) or the more the number of heads, the better the irradiation depth, and the more suitable for deeper surgery.

3. The Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light can provide the operating table with an illuminance of 140000-160000 LUX, and it is best to have a multi-levels dimming control function, too bright will affect the doctor's vision; try to avoid the beam of light on the surgical instrument and the glare, which will also affect the doctor Eyesight and vision are easy to cause eye fatigue, which is not conducive to surgeons.

4. The color temperature of the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light is about 4500K, and the color rendering index is not less than 95, so that the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light illumination does not change the patient's skin color and wound tissue color.

5. The beam diameter range of the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light is 10-25 cm, and the diameter of the beam can be adjusted by adjusting the handle (as shown in the figure below, the beam area on the ground).

6. Increasing the illuminance will inevitably cause the temperature of the lamp body and the beam to rise, which will affect the temperature of the doctor's head and the tissue of the surgical site, thereby affecting the efficiency and quality of the operation; it is precisely because of the sensitivity of temperature to patient infection, therefore, The temperature rise of the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light should be lower than 2 degrees per hour, and the temperature rise of the operating room should be controlled within 10 degrees Celsius. Similarly, the increase in temperature has a great impact on the life of electronic devices, circuits, light sources, etc. in Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light. Most of the malfunctions and damages of Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical lights are related to temperature.

7. The Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light is designed to minimize and eliminate the infrared and glare components in the Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light through the lens and filter design.

8. The Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light should be able to continuously change the position and direction during the operation, and the operation must be simple, flexible, light, fast and effective. The central part of the lamp body should be equipped with a sterilizable operating handle. The lamp should be able to be flexibly adjusted horizontally and vertically, and can be rotated 360 degrees.

9. For Fepdon Geeta Series LED surgical lighting lamp equipment shadowless surgical light with camera function or image transmission function and wireless intelligent remote control, the camera and the lamp should be integrated without interference.